Street Construction Inspections and Corrective Action Requests

DOT's Highway Inspection & Quality Assurance (HIQA) enforces the laws and rules that govern the way utilities, plumbers, contractors, other governmental agencies, and property owners perform work on the City's sidewalks, roadways and highways. DOT's inspectors also review work sites for compliance with permit stipulations, and issue violations when they find non-compliance with the laws and rules.

Transportation Department of Transportation (DOT) Dataset ydkf-mpxb 27 fields
DOWNLOAD CSV
Dataset fields
Showing 50 real records
6467303
Inspectionid: 6467303 • Permitnumber: M012016302B85 • Permitteename: TIME WARNER CABLE NEW YORK CITY LLC
Inspectionid
6467303
Permitnumber
M012016302B85
Permitteename
TIME WARNER CABLE NEW YORK CITY LLC
Permittype
CONDUIT CONSTRUCTION AND FRANCHISE-PROT
Onstreetname
WEST 47 STREET
Fromstreetname
5 AVENUE
Tostreetname
6 AVENUE
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:01:06.000Z
Inspectionresulttype
CAR (Other)
Inspectionremarks
Expansion Joints around a newly restored Sidewalk Flag with a Communications Box need to be Sealed, I/F/O 24 West 47th Street
Carnumber
20176030035
Defectivecuts
0
Feetfromcrossstreet
341
Feetfromcurb
1
Carcomments
Expansion Joints around a newly restored Sidewalk Flag with a Communications Box need to be Sealed, I/F/O 24 West 47th Street
Laneofcut
SideWalk
Trafficflow
Heavy
Crossstreetname
5 AVENUE
Createdon
2017-01-29T14:01:06.000Z
Modifiedon
2017-01-29T14:01:06.000
6467304
Inspectionid: 6467304 • Permitnumber: Q012014280103 • Permitteename: CONSOLIDATED EDISON
Inspectionid
6467304
Permitnumber
Q012014280103
Permitteename
CONSOLIDATED EDISON
Permittype
REPAIR GAS
Onstreetname
81 AVENUE
Fromstreetname
260 STREET
Tostreetname
261 STREET
Specificlocation
QL14006170-72'E/W/CL-260 ST-5'N/S/CL-81 AVE.TYP-1-
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:05:56.000Z
Inspectionresulttype
Pass
Inspectionremarks
perm roadway and sidewalk cuts are to grade.
Createdon
2017-01-29T14:05:56.000Z
Modifiedon
2017-01-29T14:05:56.000
6467305
Inspectionid: 6467305 • Permitnumber: B012016092A65 • Permitteename: THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Inspectionid
6467305
Permitnumber
B012016092A65
Permitteename
THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Permittype
MAJOR INSTALLATION - GAS
Onstreetname
20 AVENUE
Fromstreetname
BATH AVENUE
Tostreetname
CROPSEY AVENUE
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:06:01.000Z
Inspectionresulttype
Work Not Done, Permit Expired
Inspectionremarks
nothing found..
Createdon
2017-01-29T14:06:01.000Z
Modifiedon
2017-01-29T14:06:01.000
6467306
Inspectionid: 6467306 • Permitnumber: M042016308A03 • Permitteename: ETNA CONTRACTING INC.
Inspectionid
6467306
Permitnumber
M042016308A03
Permitteename
ETNA CONTRACTING INC.
Permittype
REPAIR SIDEWALK
Onstreetname
SULLIVAN STREET
Fromstreetname
PRINCE STREET
Tostreetname
SPRING STREET
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T13:56:37.000Z
Inspectionresulttype
Pass
Inspectionremarks
SW acceptable
Createdon
2017-01-29T13:56:37.000Z
Modifiedon
2017-01-29T13:56:37.000
6467307
Inspectionid: 6467307 • Permitnumber: B012015181B90 • Permitteename: KEYSPAN ENERGY DELIVERY N.Y.C.
Inspectionid
6467307
Permitnumber
B012015181B90
Permitteename
KEYSPAN ENERGY DELIVERY N.Y.C.
Permittype
MAJOR INSTALLATION - GAS
Onstreetname
20 AVENUE
Fromstreetname
BATH AVENUE
Tostreetname
CROPSEY AVENUE
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:06:37.000Z
Inspectionresulttype
Pass
Inspectionremarks
s/w & r/w ok
Createdon
2017-01-29T14:06:37.000Z
Modifiedon
2017-01-29T14:06:37.000
6467308
Inspectionid: 6467308 • Permitnumber: B012015258A46 • Permitteename: KEYSPAN ENERGY DELIVERY N.Y.C.
Inspectionid
6467308
Permitnumber
B012015258A46
Permitteename
KEYSPAN ENERGY DELIVERY N.Y.C.
Permittype
REPAIR GAS
Onstreetname
ST MARKS AVENUE
Fromstreetname
BROOKLYN AVENUE
Tostreetname
NEW YORK AVENUE
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:05:23.000Z
Inspectionresulttype
Pass
Inspectionremarks
perm cut on r/w and s/w flags in compliance
Createdon
2017-01-29T14:05:23.000Z
Modifiedon
2017-01-29T14:05:23.000
6467309
Inspectionid: 6467309 • Permitnumber: B012016006A79 • Permitteename: THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Inspectionid
6467309
Permitnumber
B012016006A79
Permitteename
THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Permittype
MAJOR INSTALLATION - GAS
Onstreetname
20 AVENUE
Fromstreetname
BATH AVENUE
Tostreetname
CROPSEY AVENUE
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:07:07.000Z
Inspectionresulttype
Pass
Inspectionremarks
nothing new found..possibly under car
Createdon
2017-01-29T14:07:07.000Z
Modifiedon
2017-01-29T14:07:07.000
6467310
Inspectionid: 6467310 • Permitnumber: Q042016195A26 • Permitteename: LUIGI MASONRY WORKS & HOME IMPROVEMENT, INC.
Inspectionid
6467310
Permitnumber
Q042016195A26
Permitteename
LUIGI MASONRY WORKS & HOME IMPROVEMENT, INC.
Permittype
REPAIR SIDEWALK
Onstreetname
81 AVENUE
Fromstreetname
260 STREET
Tostreetname
261 STREET
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:06:50.000Z
Inspectionresulttype
Pass
Inspectionremarks
sidewalk repaired at time of my inspection
Createdon
2017-01-29T14:06:50.000Z
Modifiedon
2017-01-29T14:06:50.000
6467311
Inspectionid: 6467311 • Permitnumber: QNP2017029A08 • Permitteename: CONSOLIDATED EDISON
Inspectionid
6467311
Permitnumber
QNP2017029A08
Permitteename
CONSOLIDATED EDISON
Permittype
NON PERMIT
Onstreetname
37 STREET
Fromstreetname
30 AVENUE
Tostreetname
31 AVENUE
Inspectiontype
Pick-Up
Inspectiondate
2017-01-29T14:05:44.000Z
Inspectionresulttype
CAR (Other)
Inspectionremarks
F/o 30-16A gas valve cover 2 inches below grade.
Carnumber
20174250025
Defectivecuts
0
Feetfromcrossstreet
0
Feetfromcurb
3
Carcomments
F/o 30-16A gas valve cover 2 inches below grade.
Laneofcut
SideWalk
Trafficflow
Medium
Createdon
2017-01-29T14:05:44.000Z
Modifiedon
2017-01-29T14:05:44.000
6467312
Inspectionid: 6467312 • Permitnumber: Q012015278B79 • Permitteename: WELSBACH ELECTRIC CORPORATION
Inspectionid
6467312
Permitnumber
Q012015278B79
Permitteename
WELSBACH ELECTRIC CORPORATION
Permittype
REPAIR TRAFFIC STREET LIGHT
Onstreetname
81 AVENUE
Fromstreetname
261 STREET
Tostreetname
262 STREET
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:09:25.000Z
Inspectionresulttype
Pass
Inspectionremarks
fo 260-08 foundation there but no light
Createdon
2017-01-29T14:09:25.000Z
Modifiedon
2017-01-29T14:09:25.000
6467313
Inspectionid: 6467313 • Permitnumber: B012016336A36 • Permitteename: WELSBACH ELECTRIC CORP.
Inspectionid
6467313
Permitnumber
B012016336A36
Permitteename
WELSBACH ELECTRIC CORP.
Permittype
REPAIR TRAFFIC STREET LIGHT - PROTECTED
Onstreetname
LIVONIA AVENUE
Fromstreetname
VAN SINDEREN AVENUE
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:09:38.000Z
Inspectionresulttype
Pass
Inspectionremarks
Street light.
Createdon
2017-01-29T14:09:38.000Z
Modifiedon
2017-01-29T14:09:38.000
6467314
Inspectionid: 6467314 • Permitnumber: Q012016149A00 • Permitteename: THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Inspectionid
6467314
Permitnumber
Q012016149A00
Permitteename
THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Permittype
REPAIR GAS - PROTECTED
Onstreetname
122 AVENUE
Fromstreetname
BENTON STREET
Tostreetname
LUCAS STREET
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:07:51.000Z
Inspectionresulttype
Pass
Inspectionremarks
opp. 189-15, gas perm roadway cut is to grade in p/l.
Createdon
2017-01-29T14:07:51.000Z
Modifiedon
2017-01-29T14:07:51.000
6467315
Inspectionid: 6467315 • Permitnumber: B012015272C04 • Permitteename: KEYSPAN ENERGY DELIVERY N.Y.C.
Inspectionid
6467315
Permitnumber
B012015272C04
Permitteename
KEYSPAN ENERGY DELIVERY N.Y.C.
Permittype
MAJOR INSTALLATION - GAS
Onstreetname
ST MARKS AVENUE
Fromstreetname
BROOKLYN AVENUE
Tostreetname
NEW YORK AVENUE
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:10:12.000Z
Inspectionresulttype
Pass
Inspectionremarks
perm cut on r/w and s/w flags in compliance
Createdon
2017-01-29T14:10:12.000Z
Modifiedon
2017-01-29T14:10:12.000
6467343
Inspectionid: 6467343 • Permitnumber: B012016320B58 • Permitteename: VERIZON NEW YORK INC.
Inspectionid
6467343
Permitnumber
B012016320B58
Permitteename
VERIZON NEW YORK INC.
Permittype
MAJOR INSTALLATIONS - TELEPHONE
Onstreetname
5 AVENUE
Fromstreetname
18 STREET
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:19:32.000Z
Inspectionresulttype
Pass
Inspectionremarks
roadway cut
Createdon
2017-01-29T14:19:32.000Z
Modifiedon
2017-01-29T14:19:32.000
6467372
Inspectionid: 6467372 • Permitnumber: Q012015362B97 • Permitteename: CONSOLIDATED EDISON
Inspectionid
6467372
Permitnumber
Q012015362B97
Permitteename
CONSOLIDATED EDISON
Permittype
REPAIR GAS
Onstreetname
264 STREET
Fromstreetname
81 AVENUE
Tostreetname
82 AVENUE
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:30:00.000Z
Inspectionresulttype
Pass
Inspectionremarks
cut on sidewalk in good condition
Createdon
2017-01-29T14:30:00.000Z
Modifiedon
2017-01-29T14:30:00.000
6467426
Inspectionid: 6467426 • Permitnumber: Q022016350A03 • Permitteename: YU HUA CONSTRUCTION CORP.
Inspectionid
6467426
Permitnumber
Q022016350A03
Permitteename
YU HUA CONSTRUCTION CORP.
Permittype
PLACE CONTAINER ON THE STREET
Onstreetname
88 STREET
Fromstreetname
85 ROAD
Tostreetname
JAMAICA AVENUE
Inspectiontype
Active
Inspectiondate
2017-01-29T14:49:38.000Z
Inspectionresulttype
Pass
Inspectionremarks
Container placed
Createdon
2017-01-29T14:49:38.000Z
Modifiedon
2017-01-29T14:49:38.000
6467316
Inspectionid: 6467316 • Permitnumber: BNP2017029A08 • Permitteename: M SQUARE BUILDERS LLC
Inspectionid
6467316
Permitnumber
BNP2017029A08
Permitteename
M SQUARE BUILDERS LLC
Permittype
NON PERMIT
Onstreetname
OAK STREET
Fromstreetname
FRANKLIN STREET
Tostreetname
WEST STREET
Specificlocation
Oak street
Inspectiontype
Pick-Up
Inspectiondate
2017-01-29T14:03:53.000Z
Inspectionresulttype
NOV (Other)
Inspectionremarks
A/T/P/O I observed respondent or subcontractor partially closed the street with a make shift barricades restricting parking when no one on site area closed off 25' Linear feet x 6' wide without a permit to close area ID NYC DOB permit 32128049401AL
Novnumber
0700889081
Novcode
D03
Novcodedescription
Street closing without DOT permit
Detailsofviolation
A/T/P/O I observed respondent or subcontractor partially closed the street with a make shift barricades restricting parking when no one on site area closed off 25' Linear feet x 6' wide without a permit to close area ID NYC DOB permit 32128049401AL If not admitting the charge, you MUST APPEAR IN PERSON.
Createdon
2017-01-29T14:03:53.000Z
Modifiedon
2017-01-29T14:03:53.000
6467317
Inspectionid: 6467317 • Permitnumber: Q012015028E78 • Permitteename: CONSOLIDATED EDISON
Inspectionid
6467317
Permitnumber
Q012015028E78
Permitteename
CONSOLIDATED EDISON
Permittype
MAJOR INSTALL - HIGH VOLTAGE-PROTECTED
Onstreetname
2 STREET
Fromstreetname
BORDEN AVENUE
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:10:19.000Z
Inspectionresulttype
Pass
Inspectionremarks
no defect found at intersection. perm restoration at crosswalk
Createdon
2017-01-29T14:10:19.000Z
Modifiedon
2017-01-29T14:10:19.000
6467318
Inspectionid: 6467318 • Permitnumber: X012015232B58 • Permitteename: LIGHTOWER FIBER NETWORKS I,
Inspectionid
6467318
Permitnumber
X012015232B58
Permitteename
LIGHTOWER FIBER NETWORKS I,
Permittype
CONDUIT CONSTRUCTION AND FRANCHISE
Onstreetname
EAST 229 STREET
Fromstreetname
EAST 229 DRIVE NORTH
Tostreetname
EAST 229 DRIVE SOUTH
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:11:56.000Z
Inspectionresulttype
Pass
Inspectionremarks
Conduit in complaince
Createdon
2017-01-29T14:11:56.000Z
Modifiedon
2017-01-29T14:11:56.000
6467319
Inspectionid: 6467319 • Permitnumber: M012015037A12 • Permitteename: CONSOLIDATED EDISON
Inspectionid
6467319
Permitnumber
M012015037A12
Permitteename
CONSOLIDATED EDISON
Permittype
MAJOR INSTALLATION - GAS
Onstreetname
SULLIVAN STREET
Fromstreetname
PRINCE STREET
Tostreetname
WEST HOUSTON STREET
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:12:02.000Z
Inspectionresulttype
Pass
Inspectionremarks
Perm gas cut acceptable
Createdon
2017-01-29T14:12:02.000Z
Modifiedon
2017-01-29T14:12:02.000
6467320
Inspectionid: 6467320 • Permitnumber: B012016014B77 • Permitteename: NYC MAINMAN CORP.
Inspectionid
6467320
Permitnumber
B012016014B77
Permitteename
NYC MAINMAN CORP.
Permittype
REPAIR WATER
Onstreetname
63 STREET
Fromstreetname
4 AVENUE
Tostreetname
5 AVENUE
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:11:39.000Z
Inspectionresulttype
Pass
Inspectionremarks
roadway
Createdon
2017-01-29T14:11:39.000Z
Modifiedon
2017-01-29T14:11:39.000
6467321
Inspectionid: 6467321 • Permitnumber: Q012016154A68 • Permitteename: CONSOLIDATED EDISON
Inspectionid
6467321
Permitnumber
Q012016154A68
Permitteename
CONSOLIDATED EDISON
Permittype
REPAIR TRAFFIC STREET LIGHT
Onstreetname
263 STREET
Fromstreetname
80 AVENUE
Tostreetname
81 AVENUE
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:11:58.000Z
Inspectionresulttype
Pass
Inspectionremarks
Installation of Street Light. permanent trench crossing the roadway color coded and sealed
Createdon
2017-01-29T14:11:58.000Z
Modifiedon
2017-01-29T14:11:58.000
6467322
Inspectionid: 6467322 • Permitnumber: M012015161A98 • Permitteename: CONSOLIDATED EDISON
Inspectionid
6467322
Permitnumber
M012015161A98
Permitteename
CONSOLIDATED EDISON
Permittype
REPAIR GAS - PROTECTED
Onstreetname
1 AVENUE
Fromstreetname
EAST 39 STREET
Tostreetname
EAST 40 STREET
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:12:02.000Z
Inspectionresulttype
Pass
Inspectionremarks
Perm Cut around "Gas" valve box. located opp 685.
Createdon
2017-01-29T14:12:02.000Z
Modifiedon
2017-01-29T14:12:02.000
6467323
Inspectionid: 6467323 • Permitnumber: Q012016095E07 • Permitteename: WELSBACH ELECTRIC CORP.
Inspectionid
6467323
Permitnumber
Q012016095E07
Permitteename
WELSBACH ELECTRIC CORP.
Permittype
REPAIR TRAFFIC STREET LIGHT
Onstreetname
263 STREET
Fromstreetname
80 AVENUE
Tostreetname
81 AVENUE
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:13:17.000Z
Inspectionresulttype
Pass
Inspectionremarks
80-39 new foundation on sidewalk expansion joints sealed
Createdon
2017-01-29T14:13:17.000Z
Modifiedon
2017-01-29T14:13:17.000
6467324
Inspectionid: 6467324 • Permitnumber: X012015328A04 • Permitteename: CONSOLIDATED EDISON
Inspectionid
6467324
Permitnumber
X012015328A04
Permitteename
CONSOLIDATED EDISON
Permittype
MAJOR INSTALLATION - GAS
Onstreetname
JEROME AVENUE
Fromstreetname
EAST 190 STREET
Tostreetname
WEST 192 STREET
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:12:57.000Z
Inspectionresulttype
Pass
Inspectionremarks
perm final color coded in front of in front of 2575
Createdon
2017-01-29T14:12:57.000Z
Modifiedon
2017-01-29T14:12:57.000
6467325
Inspectionid: 6467325 • Permitnumber: M012014275008 • Permitteename: CONSOLIDATED EDISON
Inspectionid
6467325
Permitnumber
M012014275008
Permitteename
CONSOLIDATED EDISON
Permittype
MAJOR INSTALLATIONS - GAS-PROTECTED
Onstreetname
1 AVENUE
Fromstreetname
EAST 40 STREET
Specificlocation
5' SNC, 0' EWC, S12-21450-M, HALLEN, OTG RORY -ACS
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:13:51.000Z
Inspectionresulttype
Pass
Inspectionremarks
MAJOR INSTALLATIONS - GAS.
Createdon
2017-01-29T14:13:51.000Z
Modifiedon
2017-01-29T14:13:51.000
6467326
Inspectionid: 6467326 • Permitnumber: X012015232B59 • Permitteename: LIGHTOWER FIBER NETWORKS I,
Inspectionid
6467326
Permitnumber
X012015232B59
Permitteename
LIGHTOWER FIBER NETWORKS I,
Permittype
CONDUIT CONSTRUCTION AND FRANCHISE
Onstreetname
EAST 229 DRIVE SOUTH
Fromstreetname
EAST 229 STREET
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:13:29.000Z
Inspectionresulttype
Pass
Inspectionremarks
Conduit in complaince
Createdon
2017-01-29T14:13:29.000Z
Modifiedon
2017-01-29T14:13:29.000
6467327
Inspectionid: 6467327 • Permitnumber: M012014274009 • Permitteename: CONSOLIDATED EDISON
Inspectionid
6467327
Permitnumber
M012014274009
Permitteename
CONSOLIDATED EDISON
Permittype
REPAIR GAS - PROTECTED
Onstreetname
1 AVENUE
Fromstreetname
EAST 40 STREET
Specificlocation
*
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:14:20.000Z
Inspectionresulttype
Pass
Inspectionremarks
REPAIR GAS.
Createdon
2017-01-29T14:14:20.000Z
Modifiedon
2017-01-29T14:14:20.000
6467328
Inspectionid: 6467328 • Permitnumber: M012015079A56 • Permitteename: CONSOLIDATED EDISON
Inspectionid
6467328
Permitnumber
M012015079A56
Permitteename
CONSOLIDATED EDISON
Permittype
MAJOR INSTALLATION - GAS
Onstreetname
SULLIVAN STREET
Fromstreetname
PRINCE STREET
Tostreetname
WEST HOUSTON STREET
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:14:16.000Z
Inspectionresulttype
Pass
Inspectionremarks
Perm gas trench acceptable
Createdon
2017-01-29T14:14:16.000Z
Modifiedon
2017-01-29T14:14:16.000
6467329
Inspectionid: 6467329 • Permitnumber: B012016285B97 • Permitteename: THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Inspectionid
6467329
Permitnumber
B012016285B97
Permitteename
THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Permittype
FINAL RESTORATION ONLY
Onstreetname
FRANKLIN STREET
Fromstreetname
HURON STREET
Tostreetname
INDIA STREET
Inspectiontype
CAR Re-Inspect
Inspectiondate
2017-01-29T14:14:44.000Z
Inspectionresulttype
Pass
Inspectionremarks
Barricades removed
Createdon
2017-01-29T14:14:44.000Z
Modifiedon
2017-01-29T14:14:44.000
6467330
Inspectionid: 6467330 • Permitnumber: Q012015320A30 • Permitteename: CONSOLIDATED EDISON
Inspectionid
6467330
Permitnumber
Q012015320A30
Permitteename
CONSOLIDATED EDISON
Permittype
REPAIR TRAFFIC STREET LIGHT
Onstreetname
263 STREET
Fromstreetname
80 AVENUE
Tostreetname
81 AVENUE
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:14:39.000Z
Inspectionresulttype
Pass
Inspectionremarks
perm roadway trench is to grade.color coded and sealed
Createdon
2017-01-29T14:14:39.000Z
Modifiedon
2017-01-29T14:14:39.000
6467331
Inspectionid: 6467331 • Permitnumber: B012015335A50 • Permitteename: THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Inspectionid
6467331
Permitnumber
B012015335A50
Permitteename
THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Permittype
MAJOR INSTALLATIONS - GAS-PROTECTED
Onstreetname
63 STREET
Fromstreetname
4 AVENUE
Tostreetname
5 AVENUE
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:13:47.000Z
Inspectionresulttype
Pass
Inspectionremarks
roadway
Createdon
2017-01-29T14:13:47.000Z
Modifiedon
2017-01-29T14:13:47.000
6467332
Inspectionid: 6467332 • Permitnumber: B012016335C16 • Permitteename: WELSBACH ELECTRIC CORP.
Inspectionid
6467332
Permitnumber
B012016335C16
Permitteename
WELSBACH ELECTRIC CORP.
Permittype
REPAIR TRAFFIC STREET LIGHT
Onstreetname
LIVONIA AVENUE
Fromstreetname
HINSDALE STREET
Tostreetname
SNEDIKER AVENUE
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:17:09.000Z
Inspectionresulttype
Pass
Inspectionremarks
Street light.
Createdon
2017-01-29T14:17:09.000Z
Modifiedon
2017-01-29T14:17:09.000
6467354
Inspectionid: 6467354 • Permitnumber: M012014251B31 • Permitteename: EXTENET SYSTEMS(NEW YORK)INC
Inspectionid
6467354
Permitnumber
M012014251B31
Permitteename
EXTENET SYSTEMS(NEW YORK)INC
Permittype
CONDUIT CONSTRUCTION AND FRANCHISE
Onstreetname
SULLIVAN STREET
Fromstreetname
PRINCE STREET
Tostreetname
WEST HOUSTON STREET
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:16:54.000Z
Inspectionresulttype
Pass
Inspectionremarks
Perm trench acceptable
Createdon
2017-01-29T14:16:54.000Z
Modifiedon
2017-01-29T14:16:54.000
6467333
Inspectionid: 6467333 • Permitnumber: B012015294C16 • Permitteename: VERIZON NEW YORK INC.
Inspectionid
6467333
Permitnumber
B012015294C16
Permitteename
VERIZON NEW YORK INC.
Permittype
MAJOR INSTALLATION - TELEPHONE-PROTECTED
Onstreetname
KINGSLAND AVENUE
Fromstreetname
JACKSON STREET
Tostreetname
SKILLMAN AVENUE
Inspectiontype
CAR Re-Inspect
Inspectiondate
2017-01-29T14:14:09.000Z
Inspectionresulttype
NOV (Other)
Inspectionremarks
A/T/P/O I observed respondent did not re-seal the outer joints of permanent trench openings now cracked and open after previous request by car #20160920403 no repairs made at this time ID by IBM permanent color code & permit
Novnumber
0700889256
Novcode
D5A
Novcodedescription
Failure to properly seal and maintain the wearing course
Detailsofviolation
A/T/P/O I observed respondent did not re-seal the outer joints of permanent trench openings now cracked and open after previous request by car #20160920403 no repairs made at this time ID by IBM permanent color code & permit If not admitting the charge, you MUST APPEAR IN PERSON.
Createdon
2017-01-29T14:14:09.000Z
Modifiedon
2017-01-29T14:14:09.000
6467334
Inspectionid: 6467334 • Permitnumber: B012016207A82 • Permitteename: CONSOLIDATED EDISON
Inspectionid
6467334
Permitnumber
B012016207A82
Permitteename
CONSOLIDATED EDISON
Permittype
REPAIR ELECTRIC/COMMUNICATIONS
Onstreetname
GREENPOINT AVENUE
Fromstreetname
NEWELL STREET
Tostreetname
PROVOST STREET
Inspectiontype
CAR Re-Inspect
Inspectiondate
2017-01-29T14:17:08.000Z
Inspectionresulttype
Pass
Inspectionremarks
Plate removed at time
Createdon
2017-01-29T14:17:08.000Z
Modifiedon
2017-01-29T14:17:08.000
6467335
Inspectionid: 6467335 • Permitnumber: B012016092B24 • Permitteename: THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Inspectionid
6467335
Permitnumber
B012016092B24
Permitteename
THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Permittype
MAJOR INSTALLATION - GAS
Onstreetname
BATH AVENUE
Fromstreetname
20 AVENUE
Tostreetname
BAY 25 STREET
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:17:24.000Z
Inspectionresulttype
Work Not Done, Permit Expired
Inspectionremarks
nothing found..
Createdon
2017-01-29T14:17:24.000Z
Modifiedon
2017-01-29T14:17:24.000
6467336
Inspectionid: 6467336 • Permitnumber: B012015334C15 • Permitteename: RR PLUMBING SERVICES CORP
Inspectionid
6467336
Permitnumber
B012015334C15
Permitteename
RR PLUMBING SERVICES CORP
Permittype
REPAIR WATER - PROTECTED
Onstreetname
63 STREET
Fromstreetname
4 AVENUE
Tostreetname
5 AVENUE
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:17:01.000Z
Inspectionresulttype
Pass
Inspectionremarks
roadway
Createdon
2017-01-29T14:17:01.000Z
Modifiedon
2017-01-29T14:17:01.000
6467337
Inspectionid: 6467337 • Permitnumber: S012016162B13 • Permitteename: THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Inspectionid
6467337
Permitnumber
S012016162B13
Permitteename
THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Permittype
PAVEMENT CORES
Onstreetname
HOPKINS AVENUE
Fromstreetname
DURANT AVENUE
Tostreetname
HOOPER AVENUE
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:17:12.000Z
Inspectionresulttype
Pass
Inspectionremarks
No rwy work visible, perhaps s/w grass area.
Createdon
2017-01-29T14:17:12.000Z
Modifiedon
2017-01-29T14:17:12.000
6467338
Inspectionid: 6467338 • Permitnumber: B012016175A68 • Permitteename: TRIBORO WATER MAIN AND SEWER CORP.
Inspectionid
6467338
Permitnumber
B012016175A68
Permitteename
TRIBORO WATER MAIN AND SEWER CORP.
Permittype
REPAIR WATER - SEWER
Onstreetname
5 AVENUE
Fromstreetname
23 STREET
Tostreetname
24 STREET
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:17:46.000Z
Inspectionresulttype
Pass
Inspectionremarks
roadway cut
Createdon
2017-01-29T14:17:46.000Z
Modifiedon
2017-01-29T14:17:46.000
6467339
Inspectionid: 6467339 • Permitnumber: B012017029A00 • Permitteename: THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Inspectionid
6467339
Permitnumber
B012017029A00
Permitteename
THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Permittype
REPAIR GAS - PROTECTED
Onstreetname
EASTERN PARKWAY
Fromstreetname
BEND
Tostreetname
UNDERHILL AVENUE
Inspectiontype
E-Number
Inspectiondate
2017-01-29T14:17:39.000Z
Inspectionresulttype
Pass
Inspectionremarks
Service gas leak, sidewalk venting .
Createdon
2017-01-29T14:17:39.000Z
Modifiedon
2017-01-29T14:17:39.000
6467340
Inspectionid: 6467340 • Permitnumber: B012015299A85 • Permitteename: KEYSPAN ENERGY DELIVERY N.Y.C.
Inspectionid
6467340
Permitnumber
B012015299A85
Permitteename
KEYSPAN ENERGY DELIVERY N.Y.C.
Permittype
MAJOR INSTALLATIONS - GAS-PROTECTED
Onstreetname
63 STREET
Fromstreetname
4 AVENUE
Tostreetname
5 AVENUE
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:18:51.000Z
Inspectionresulttype
Pass
Inspectionremarks
roadway
Createdon
2017-01-29T14:18:51.000Z
Modifiedon
2017-01-29T14:18:51.000
6467344
Inspectionid: 6467344 • Permitnumber: B042016299A31 • Permitteename: AICO INC.
Inspectionid
6467344
Permitnumber
B042016299A31
Permitteename
AICO INC.
Permittype
REPAIR SIDEWALK
Onstreetname
13 AVENUE
Fromstreetname
78 STREET
Tostreetname
79 STREET
Inspectiontype
CAR Re-Inspect
Inspectiondate
2017-01-29T13:55:09.000Z
Inspectionresulttype
NOV (Other)
Inspectionremarks
ATPO I observed the above respondent failed to seal expansion joints as per CAR #20165410891 issued 12/19/16
Novnumber
0700889402
Novcode
D69
Novcodedescription
Failure to obtain DOT permit for street plate covering defective condition
Detailsofviolation
ATPO I observed the above respondent failed to seal expansion joints as per CAR #20165410891 issued 12/19/16 If not admitting the charge, you MUST APPEAR IN PERSON.
Createdon
2017-01-29T13:55:09.000Z
Modifiedon
2017-01-29T13:55:09.000
6467345
Inspectionid: 6467345 • Permitnumber: Q012015358A12 • Permitteename: THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Inspectionid
6467345
Permitnumber
Q012015358A12
Permitteename
THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Permittype
MAJOR INSTALLATIONS - GAS-PROTECTED
Onstreetname
122 AVENUE
Fromstreetname
BENTON STREET
Tostreetname
LUCAS STREET
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:19:13.000Z
Inspectionresulttype
Pass
Inspectionremarks
gas perm roadway cut is to grade in p/l.
Createdon
2017-01-29T14:19:13.000Z
Modifiedon
2017-01-29T14:19:13.000
6467346
Inspectionid: 6467346 • Permitnumber: Q012014356B19 • Permitteename: BEST WORK INC.
Inspectionid
6467346
Permitnumber
Q012014356B19
Permitteename
BEST WORK INC.
Permittype
RESET, REPAIR OR REPLACE CURB
Onstreetname
60 PLACE
Fromstreetname
60 COURT
Tostreetname
60 DRIVE
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:20:53.000Z
Inspectionresulttype
Pass
Inspectionremarks
curb installed, joints sealed
Createdon
2017-01-29T14:20:53.000Z
Modifiedon
2017-01-29T14:20:53.000
6467347
Inspectionid: 6467347 • Permitnumber: B012016092B52 • Permitteename: THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Inspectionid
6467347
Permitnumber
B012016092B52
Permitteename
THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Permittype
MAJOR INSTALLATION - GAS
Onstreetname
FREEMAN STREET
Fromstreetname
FRANKLIN STREET
Tostreetname
WEST STREET
Inspectiontype
CAR Re-Inspect
Inspectiondate
2017-01-29T14:21:37.000Z
Inspectionresulttype
Pass
Inspectionremarks
Repairs made regraded 2 cuts ok
Createdon
2017-01-29T14:21:37.000Z
Modifiedon
2017-01-29T14:21:37.000
6467348
Inspectionid: 6467348 • Permitnumber: B012015252A33 • Permitteename: KEYSPAN ENERGY DELIVERY N.Y.C.
Inspectionid
6467348
Permitnumber
B012015252A33
Permitteename
KEYSPAN ENERGY DELIVERY N.Y.C.
Permittype
MAJOR INSTALLATIONS - GAS-PROTECTED
Onstreetname
63 STREET
Fromstreetname
4 AVENUE
Tostreetname
5 AVENUE
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:21:16.000Z
Inspectionresulttype
Pass
Inspectionremarks
roadway
Createdon
2017-01-29T14:21:16.000Z
Modifiedon
2017-01-29T14:21:16.000
6467349
Inspectionid: 6467349 • Permitnumber: B012016330A15 • Permitteename: CONSOLIDATED EDISON
Inspectionid
6467349
Permitnumber
B012016330A15
Permitteename
CONSOLIDATED EDISON
Permittype
MAJOR INSTALLATIONS - HIGH VOLTAGE
Onstreetname
LIVONIA AVENUE
Fromstreetname
HINSDALE STREET
Tostreetname
SNEDIKER AVENUE
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:22:09.000Z
Inspectionresulttype
Pass
Inspectionremarks
Trench in r/w.
Createdon
2017-01-29T14:22:09.000Z
Modifiedon
2017-01-29T14:22:09.000
6467350
Inspectionid: 6467350 • Permitnumber: B012016095B96 • Permitteename: THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Inspectionid
6467350
Permitnumber
B012016095B96
Permitteename
THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Permittype
MAJOR INSTALLATION - GAS
Onstreetname
BATH AVENUE
Fromstreetname
BAY 13 STREET
Tostreetname
BAY 14 STREET
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:22:56.000Z
Inspectionresulttype
Pass
Inspectionremarks
perm to grade..
Createdon
2017-01-29T14:22:56.000Z
Modifiedon
2017-01-29T14:22:56.000
6467351
Inspectionid: 6467351 • Permitnumber: S012016356A00 • Permitteename: THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Inspectionid
6467351
Permitnumber
S012016356A00
Permitteename
THE BROOKLYN UNION GAS COMPANY D/B/A NATIONAL GRID NY
Permittype
REPAIR GAS
Onstreetname
LEGION PLACE
Fromstreetname
HYLAN BOULEVARD
Tostreetname
NARROWS ROAD SOUTH
Inspectiontype
Post-Audit
Inspectiondate
2017-01-29T14:11:11.000Z
Inspectionresulttype
CAR (Sunken Cut)
Inspectionremarks
1 of 2 cuts i/f/o # 29 is perm to grade & temp sunken 2"/overdue for final. 2 cuts i/f/o # 33 perm to grade. Cut in s/w-apron i/f/o # 32 overdue for final. Bar holes not plugged from #'s 29-35. Cones not removed after cuts paved. C.A.R was issued.
Carnumber
20173160062
Defectivecuts
0
Feetfromcrossstreet
0
Feetfromcurb
0
Carcomments
Temporary restoration i/f/o address # 29 was sunken 2" and overdue to be made final. Temporary restoration in the sidewalk and apron i/f/o address # 32 is overdue to be made final. Plug bar holes from address #'s 29-35 & remove safety cones.
Laneofcut
Parking
Trafficflow
Light
Crossstreetname
NARROWS ROAD SOUTH
Createdon
2017-01-29T14:11:11.000Z
Modifiedon
2017-01-29T14:11:11.000